Post has attachment
Under the action of rotating disk and misting device, water turns into ultra small droplets by the centrifugal force, which enlarges the surface of evaporation tremendously. And the airflow, powered by powerful fan, greatly enhances the wind speed of the liquid surface, so that the evaporation of water is much higher than average. While during the evaporating, it absorbs heat, reduces the temperature, and meanwhile, improves the air humidity, reduces dust, cleans the air. So it is called centrifugal mist fan.

Improve the quality of the air
Reduces the dust
Cooling fast
No high pressure
Low power consumption

Post has attachment
Under the action of rotating disk and misting device, water turns into ultra small droplets by the centrifugal force, which enlarges the surface of evaporation tremendously. And the airflow, powered by powerful fan, greatly enhances the wind speed of the liquid surface, so that the evaporation of water is much higher than average. While during the evaporating, it absorbs heat, reduces the temperature, and meanwhile, improves the air humidity, reduces dust, cleans the air. So it is called centrifugal mist fan.

Improve the quality of the air
Reduces the dust
Cooling fast
No high pressure
Low power consumption

Post has attachment
Re-usable fire extinguisher

FEATURES AND BENEFITS

Availability of safety due to its immediate extinguishing performance at the site of a fire!

Broad operating capability by being suited for Classes A, B and F

Ability to provide full extinguishing performance at any orientation (upright, upside down, on the side = 360°)

High extinguishing performance despite the small size of the extinguishing system-Intuitive, easy and safe usage even for inexperienced users

Ergonomically designed handle that allows operation by either a small child's hand or by large hands and firemen’s gloves-

Protection against inadvertent release (operator error)

Spraying performance is almost constant over the entire extinguishing period -


Easy to use by use of lightweight plastic parts, minimum weight

Applicable for electrical installations up to 1000 V (minimum spray distance 1 m)-

No maintenance and no maintenance costs within the service life of 3 years
PhotoPhotoPhoto
5/23/16
3 Photos - View album

Post has attachment
The Revolutionary Fire Extinguisher and Alarm System


Fire Extinguisher ball is a kind of shaped ball extinguisher. When simply thrown into the fire, it would activate within 3 seconds and effectively disperse extinguishing chemicals. When a fire occurs and no one is present, fire extinguisher ball will self-activate when it comes into contact with fire and give loud noise to warn the people nearby. Due to this feature, it can be placed in many fire prone areas, such as electrical circuit breakers, or kitchen, cars, hotels, etc. There is no special training or skill required to operate the ball and no need to face any dangers. No inspection and maintenance are required for the product life span for 5 years.Fire Extinguisher ball is a kind of shaped ball extinguisher. When simply thrown into the fire, it would activate within 3 seconds and effectively disperse extinguishing chemicals. When a fire occurs and no one is present, fire extinguisher ball will self-activate when it comes into contact with fire and give loud noise to warn the people nearby. Due to this feature, it can be placed in many fire prone areas, such as electrical circuit breakers, or kitchen, cars, hotels, etc. There is no special training or skill required to operate the ball and no need to face any dangers. No inspection and maintenance are required for the product life span for 5 years.






The fire fighting problems for traditional extinguishers
We have to recognize that 90% of ordinary people don’t know how to use the fire fighting equipment when faced with real fire situations.
Have you ever been one of those people, who found themselves unable to use the fire extinguishers in real fire
situation due to the following reasons?

You lack training on proper effective use
Its bulky and heavy weight makes it difficult to carry when it is some distance from the fire
You need to get close to the fire and get exposed to the smoke which causes health problem

The revolution of fire extinguishing ball offers you advantages that exceed the conventional methods.
Light Weight — 1.3 Kilogram, shapes of a ball even the old and children can use it easily.
Easy to Use — Just throw it into the fire or install it in any fire risk areas.
Safe to use — No need to get close to the fire. No-toxic to the environment. Fire Extinguishing Ball is made from human
and environmental friendly materials. The outward driving force from activation of the ball does not harm to
human and environment.
Maintenance Free — For a period of 5 years without maintenance, always on guard for you with its unique capability to emit loud noise of less than 140dB as a fire alarm upon activation.

Wide Application
Fire Extinguishing Ball can be placed on a shelf top, tabletop, along the hallway or any visible area of easy access.
Fire Extinguishing Ball is best mounted in high risk areas such as kitchens, electrical circuit breakers, overloaded
electrical outlets, or near fireplaces.

How to Use Fire Extinguishing Ball
(Active Use) Throwing Fire Extinguisher ball into the fire
When a fire erupts, take the nearest available fire extinguishing ball and simply throw into the fire. The ball will naturally fall into the base of the flames, where it is most needed, and activate within 3 seconds. No need to pull pins, or to get close to the fire. No special training or skills required.

(Passive Use) Self Activating Mount.
One of the great benefits of Fire Extinguishing Ball is the fact that it can self activate in the presence of fire when no-one is present. If
positioned in the appropriate high-risk area where most fires are likely to start, it will self activate upon reaching the appropriate temperature and extinguish the fire.


Technical Specification:
Weight of extinguishing powder mixture: 1.3 +/- 0.2 kg.
Total weight of the agent: 1.5 +- 0.2 kg.
NEC: 4.0 g
Diameter : 147 mm
Warning audio signal: 120 dB (Impulse Noise)
Activation time: 3 – 10 sec with flame
Effective extinguish area: 1.3Kg – 3 cubic meter



Package:
1 piece in color box-17.2*17.2*16.5cm
12pieces in Carton- 57*37*37.5cm
N.W & G.W: 16.8 / 18.00Kg
Photo

Post has attachment
Smoke detectors are one of those amazing inventions that, because of mass production, cost practically nothing. You can get a smoke detector for as little as $7. And while they cost very little, smoke detectors save thousands of lives each year.

In fact,it is recommended that every home have one smoke detector per floor.All smoke detectors consist of two basic parts: a sensor to sense the smoke and a very loud electronic horn to wake people up. Smoke detectors can run off of a 9-volt battery or 120-volt house current.

In this article, we will examine the two most common types of smoke detectors used today: photoelectric detectors and ionization detectors. And, we'll also take a look inside an ionization detector.

Independent Fire Smoke Alarm Detector CE/RoHS Approved

The detector is suitable for detect the smoke in house, shop, hotel, restaurant, office building, school, bank, library, computer house and storehouse etc. Standalone surface mounted, easy operate, Built-in IC card, stable performance, high sensitivity Apply optical smoke test room, With buzzer, alarm independently, 9V battery, static current: ≤10uA, alarm current: ≤12mA, Low power alarm, Alarm volume: ≥85dB, Temperature range: -10~50?C, Humidity: ≤95%RH, Size: Φ107X34MM

How to Install a Hardwired Smoke Alarm Part 3

A new smoke alarm is mounted and wired in the suspended drywall ceiling for the basement living room using an old work electrical box. NM-B 14/3 cable is pulled from an existing smoke alarm to power and interconnect the new smoke detector.

Install the Old Work Electrical Box in the Drywall Ceiling

After pulling NM-B 14/3 cable along the floor joists and fastening it with insulated cable staples every 4 or 5 feet, I wedged myself into the crawlspace above the finished basement and reached out as far as I could to position the electrical box on the suspended drywall ceiling above the basement living room.

The smoke alarm must be at least 4 inches away from the walls and I?m at least 2 feet away here.I positioned the old work electrical box parallel to the metal stringers and traced the outline of the box on the drywall ceiling with an pen. The box outline is highlighted in red for better viewing. Note: Do not trace around the tabs on the ends of the old work box because the tabs must seat against the face of the drywall to so the box doesn't pull through the drywall mounting hole.

I slipped the old work electrical box in the drywall ceiling to ensure it would fit when I installed the bop from the finished side of the ceiling. It fit perfectly the first time.
PhotoPhotoPhoto
5/23/16
3 Photos - View album
Wait while more posts are being loaded