The connecting slabs to footing often fail to provide water tightness to basement due to crack due to stress concentration and raft foundation is best suited.
4
Add a comment...

Rajib Barua

Shared publicly  - 
The task required for micropile installation should consist of required engineering & design services including supervision, materials, labor, and equipment….
4
Add a comment...

Rajib Barua

Shared publicly  - 
The casing is used in micropile construction to bear loads or to reduce deflection. IBC provided thickness limitation > 4.8 mm (3/16 inch).
6
Add a comment...

Rajib Barua

Shared publicly  - 
Tabulated values for presumptive lateral bearing capacity of soil should be increased for every additional foot of vertical depth up to 15 times.
5
Add a comment...

Rajib Barua

Shared publicly  - 
The properties of high PH, leads to gaseous loss when urea and fertilizers having ammonium compounds are used in surface of Black Cotton Soil.
4
Add a comment...
Have him in circles
230 people
svetlana soldatova's profile photo
Wolf Cocklin (Wolfcat)'s profile photo
Recomedic Rehab's profile photo
East Asia Forum's profile photo
Jovan White's profile photo
Ready-Mix Concrete's profile photo
Erich Martian's profile photo
sophie gillen's profile photo
Юлия Оноприенко's profile photo

Rajib Barua

Shared publicly  - 
Dampproofing foundation wall should consist of bituminous materials, cement modified with acrylic resin, Coating of 1/8” thick surface bonding materials…..
5
Add a comment...

Rajib Barua

Shared publicly  - 
Thus floating raft foundation provides us a way to support structure on compressible soil which may not be possible by other methods.
4
Add a comment...

Rajib Barua

Shared publicly  - 
For a rise in 17oC temperature, concrete demands (2-6)% more water which leads an increase of < 5kg/m3 cement content.
5
Add a comment...

Rajib Barua

Shared publicly  - 
The depth of plain concrete and masonry unit foundation should be equal or more than 2 times of projection beyond column, wall and pier.
4
Add a comment...

Rajib Barua

Shared publicly  - 
Concrete repair starts with possible modification or adjustments to prevent cause of deterioration…..
4
Add a comment...
People
Have him in circles
230 people
svetlana soldatova's profile photo
Wolf Cocklin (Wolfcat)'s profile photo
Recomedic Rehab's profile photo
East Asia Forum's profile photo
Jovan White's profile photo
Ready-Mix Concrete's profile photo
Erich Martian's profile photo
sophie gillen's profile photo
Юлия Оноприенко's profile photo
Basic Information
Gender
Male