I'm big fan of CMD_EI_API and VMD_EI_API classes. I use them to create, update and delete customer and vendor master data, including contact persons, partners and all data you have in XD02/XK02 transaction. Also to update Z fields from all customer and vendor related tables. But lately after upgrade from 7.40 SP5 to 7.40 SP16 the method maintain_bapi was not saving the changes to the customers.

After a while I've found out that I have to call additionally the method update_modules and now the customer was saved.
Add a comment...

Post has attachment
Public
Add a comment...

Post has attachment
I was always missing a small functionality in Eclipse - a Favourite SAP T-Codes which we all know form SAP Menu. I know to you can call SMEN transaction using Alt+F8 but it does not fill the simplicity requirement. That's why I started to ask about the possibility to have favourite T-Codes view somewhere in ADT in Eclipse. I rather thought that Thomas, the product owner of ADT would say that they will implement this in one of next releases, but instead he encourage me to do it myself.
Add a comment...

Post has attachment
If you would ask me if I would write something about SAP Script then I would definitely answer "Hell no!". I hate SAP Script to be honest, it has for me only one advantage - speed of printout if you compare it to Adobe Forms, but the rest for me..... is against.

Today I faces a really strange behaviour of one of the invoice printouts, one of the fields which was showing the tax percentage, was showing wrong value if the print program was called for the second time.

The first output was OK, 8,00 % as value.

But when I directly show again the preview of the same invoice then, the value was changed to 0,80 %.
Add a comment...

Post has attachment
My session from SAP Inside Track in Wrocław which took place on 27.05.2107. Due to many questions durng the session and limited time, I could not raise all points which I wanted to raise. But at least some of them are covered.
Add a comment...

Post has attachment
Dark theme is available in Eclipse since a long time, but there were many problems with easy setting of all colors in editors, windows and popups.

Sometimes you had to even adjust your system settings to be able to adjust some colors.

This discouraged many persons to switch to the dark side of eclipse.

But now there is a new hope for it!
Add a comment...

Post has attachment
This time the problem which I solved was not an ABAP problem, although at the beginning I thought it is, as while creating of deliveries without reference in standard transaction were done correctly without any issues, then when I tried to do it in ABAP, I always received the error VL473 - Copying is not poss.because an entry is missing in Table TVCPL.

I thought that this is some kind of nonsense as with standard t-code it was working correctly, so I tried several FM to create deliveries without reference but always with the same result as you can see on picture bellow.
Add a comment...

Post has attachment
To continue previous two posts about re-exploding and deleting subcontracting BOM of purchase requisition item, let me describe you how to do the same thing with subcontracting BOM of purchase order line.

The main part is again to use FM ME_COMPONENTS_MAINTAIN and ME_COMPONENTS_UPDATE_PREPARE , but this time there is no easy way to fill MDPA and MDLB structures which are needed here.
So I had to use CL_PO_HEADER_HANDLE_MM and IF_PURCHASE_ORDER_MM to fetch all data from purchase order and to move them to MDPA and MDLB structures. Once it was ready the rest was peanuts and I could get rid of using this two buttons :-)
Add a comment...

Post has attachment
In previous post I've shown how to re-explode subcontracting components of purchase requisition using FM ME_COMPONENTS_MAINTAIN and ME_COMPONENTS_UPDATE_PREPARE . Using very similar code you can delete completly it's BOM.

You may wonder why would need to delete subcontracting BOM? This is not possible in standard transaction ME52N and in most cases it makes no sense to have the subcontracting item without BOM. But in the case that you don't want that components are taken into consideration by MRP until you really need this then it could be helpful.
Add a comment...

Post has attachment
I faced lately a small issue in one of the process in our company, I needed to re-explode the BOM of subcontracting item in purchase requisition. Normally users goes to ME52N and press "Explode BOM" button, but I needed to do this from ABAP side.

I started with IF_PURCHASE_REQUISITION but although there is a method "explode_bom" for item, then it was calling the screen with the results instead of selecting and updating components in the database. IF_BOM_MM didn't helped as well.