Water staining was noted in the attic in multiple locations. The staining is in the vicinity of gutters that are filled with debris. This situation may potentially be allowing water to back up into the fascia board resulting in the water staining. I recommend further evaluation by a licensed professional roofer.
Photo
Add a comment...

Post has attachment
The fasteners that secure the electrical distribution panel cover are tipped. I recommend that flat tipped fasteners be utilized at this area for safety purposes.
Photo
Add a comment...

Post has attachment
The front entry way steps are beginning to deteriorate. The failing mortar joints at the pictured portions of brick should be re pointed. If unaddressed these bricks will become loose. I recommend that this work be performed by a qualified person
Photo
Add a comment...

Post has attachment
The neoprene boots at the pictured plumbing stacks are improperly installed. These boots are designed to shed water. The current installation creates a cupping effect which will eventually allow rain water entry into the attic. Repairs should be performed by a licensed professional roofer
Photo
Add a comment...

Post has attachment
The heat under performed at the pictured laundry room supply register. The ductwork in the loft appeared to be kinked, restricting air flow to this area. I recommend repairs be performed by a licensed HVAC professional.
Photo
Add a comment...

Post has attachment
The dishwasher kick plate was not installed, instead it is stored inside the appliance and was saturated. This indicates that the dishwasher was operated with the kick plate inside the unit. I recommend further evaluation by an appliance service specialist
Photo
Add a comment...

Post has attachment
The garage door operators are using an extension cord as permanent wiring, and should have individual outlets installed at each device (GFCI recommended). This is considered unsafe and needs correcting. All repairs involving wiring should be performed by a licensed professional electrician
Photo
Add a comment...

Post has attachment
The condensate discharge line for the high efficiency furnace terminates in the crawlspace. Introducing moisture into the crawlspace is poor practice and is conducive with mold growth. I recommend that this line be plumbed to the outside of the home.
Photo
Add a comment...

Post has attachment
The mortar wash used at the chimney crown has deteriorated allowing rain water to damage the mortar joint between the pictured portion of brick. Further deterioration will occur if unaddressed. I recommend that these areas be re pointed by a licensed professional contractor.